Your browser doesn't support javascript.
Mostrar: 20 | 50 | 100
Resultados 1 - 4 de 4
Filtrar
Añadir filtros

Tipo del documento
Intervalo de año
1.
Int J Environ Res Public Health ; 19(21)2022 Oct 23.
Artículo en Inglés | MEDLINE | ID: covidwho-2082239

RESUMEN

BACKGROUND: Standardized methods for testing Viral Filtration Efficiency (VFE) of tissues and devices are lacking and few studies are available on aerosolizing, sampling and assessing infectivity of SARS-CoV-2 in controlled laboratory settings. NanoAg-coated endonasal filters appear a promising aid for lowering viable virus inhalation in both adult and younger populations (e.g., adolescents). OBJECTIVE: to provide an adequate method for testing SARS-CoV-2 bioaerosol VFE of bio-gel Ag nanoparticles endonasal filters, by a model system, assessing residual infectivity as cytopathic effect and viral proliferation on in vitro cell cultures. METHODS: A SARS-CoV-2 aerosol transmission chamber fed by a BLAM aerosol generator produces challenges (from very high viral loads (105 PFU/mL) to lower ones) for endonasal filters positioned in a Y shape sampling port connected to a Biosampler. An aerosol generator, chamber and sampler are contained in a class II cabinet in a BSL3 facility. Residual infectivity is assessed from aliquots of liquid collecting bioaerosol, sampled without and with endonasal filters. Cytopathic effect as plaque formation and viral proliferation assessed by qRT-PCR on Vero E6 cells are determined up to 7 days post inoculum. RESULTS: Each experimental setting is replicated three times and basic statistics are calculated. Efficiency of aerosolization is determined as difference between viral load in the nebulizer and in the Biosampler at the first day of experiment. Efficiency of virus filtration is calculated as RNA viral load ratio in collected bioaerosol with and without endonasal filters at the day of the experiment. Presence of infectious virus is assessed by plaque forming unit assay and RNA viral load variations. CONCLUSIONS: A procedure and apparatus for assessing SARS-CoV-2 VFE for endonasal filters is proposed. The apparatus can be implemented for more sophisticated studies on contaminated aerosols.


Asunto(s)
COVID-19 , Nanopartículas del Metal , Adulto , Adolescente , Humanos , SARS-CoV-2 , Aerosoles y Gotitas Respiratorias , COVID-19/prevención & control , Plata , ARN
2.
Atmosphere ; 13(2):340, 2022.
Artículo en Inglés | MDPI | ID: covidwho-1704303

RESUMEN

The airborne route of transmission of SARS-CoV-2 was confirmed by the World Health Organization in April 2021. There is an urge to establish standardized protocols for assessing the concentration of SARS-CoV-2 RNA in air samples to support risk assessment, especially in indoor environments. Debates on the airborne transmission route of SARS-CoV-2 have been complicated because, among the studies testing the presence of the virus in the air, the percentage of positive samples has often been very low. In the present study, we report preliminary results on a study for the evaluation of parameters that can influence SARS-CoV-2 RNA recovery from quartz fiber filters spotted either by standard single-stranded SARS-CoV-2 RNA or by inactivated SARS-CoV-2 virions. The analytes were spiked on filters and underwent an active or passive sampling;then, they were preserved at −80 °C for different numbers of days (0 to 54) before extraction and analysis. We found a mean recovery of 2.43%, except for the sample not preserved (0 days) that showed a recovery of 13.51%. We found a relationship between the number of days and the recovery percentage. The results presented show a possible issue that relates to the quartz matrix and SARS-CoV-2 RNA recovery. The results are in accordance with the already published studies that described similar methods for SARS-CoV-2 RNA field sampling and that reported non-detectable concentrations of RNA. These outcomes could be false negatives due to sample preservation conditions. Thus, until further investigation, we suggest, as possible alternatives, to keep the filters: (i) in a sealed container for preservation at 4 °C;and (ii) in a viral transport medium for preservation at a temperature below 0 °C.

3.
Int J Environ Res Public Health ; 18(21)2021 10 24.
Artículo en Inglés | MEDLINE | ID: covidwho-1480773

RESUMEN

Severe acute respiratory syndrome coronavirus type 2 (SARS-CoV-2) is mainly transmitted through respiratory droplets, aerosols, or direct contact with fomites from an infected subject. It has been reported that SARS-CoV-2 is stable and viable in aerosol up to 16 h in controlled laboratory conditions. However, the aerosolization conditions varied a lot between the studies. In this work, an experimental laboratory model of SARS-CoV-2 aerosolization was established, employing an impinger nebulizer, a cylindrical chamber for aerosol travel, and a SKC biosampler for the collection of particles. The efficiency of the system was assessed based on the molecular determination of the viral load in the nebulizer after the aerosolization and in the aerosol collected at the end of the travel. Moreover, the residual infectivity was tested in vitro on the Vero E6 cell line, through the observation of the cytopathic effect (CPE), and the quantification of the viral load in the supernatants at 7 days post inoculation (dpi). A high RNA viral load was found in the SKC biosampler after aerosolization, indicating that it was possible to transport a high virus titer through the 30-cm chamber with all the dilutions (initial 105, 104, 103 plaque forming unit-PFU/mL). At the 7 dpi, an increment of the RNA viral load was determined for the dilutions 105 and 104 PFU/mL tested, while only the initial 105 PFU/mL resulted in visible CPE. Our findings allowed us to achieve the resilience of SARS-CoV-2 in aerosol form, at a concentration comparable to those reported for clinical samples. This mode of transmission should be considered for the mitigation and preventive measures to counteract SARS-CoV-2 spreading.


Asunto(s)
COVID-19 , SARS-CoV-2 , Aerosoles , Fómites , Humanos , Laboratorios
4.
Environ Res ; 198: 111200, 2021 07.
Artículo en Inglés | MEDLINE | ID: covidwho-1201877

RESUMEN

The relevance of airborne exposure to SARS-CoV-2 in indoor environments is a matter of research and debate, with special importance for healthcare low-risk settings. Experimental approaches to the bioaerosol sampling are neither standardized nor optimized yet, leading in some cases to limited representativity of the temporal and spatial variability of viral presence in aerosols. Airborne viral viability moreover needs to be assessed. A study has been conducted collecting five 24-h PM10 samples in a COVID-19 geriatric ward in late June 2020, and detecting E and RdRp genes by RT-qPCR with a Ct between 36 and 39. The viral RNA detection at Ct = 36 was related to the maximal numerosity of infected patients hosted in the ward. Lacking a direct infectivity assessment for the collected samples an experimental model has been defined, by seeding twelve nasopharyngeal swab extracts from COVID-19 positive patients on Vero E6 cells; only the four extracts with a viral load above E+10 viral copies (approximately Ct<24) have been able to establish a persistent infection in vitro. Therefore, the cytopathic effect, a key feature of residual infectivity, could be considered unlikely for the environmental PM10 samples showing amplification of viral RNA at Ct = 36 or higher. A standardization of airborne SARS-CoV-2 long-term monitoring and of environmental infectivity assessment is urgently needed.


Asunto(s)
Contaminación del Aire Interior , COVID-19 , Aerosoles , Anciano , Monitoreo del Ambiente , Humanos , SARS-CoV-2
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA